Atex and machine safety management in a compact 45 mm format
Atex dual-channel insulation barrier and controller for built-in machinery safety
Atex safety
ATEX standards
EN 60079-0
EN 60079-11
EN 60079-25
EN 60079-26
ATEX marking
[Ex ia] IIC Ga
[Ex ia] IIIC Da
II(1)GD
Product used in combination with the "ANATOM78S- (PL or OX)-EEX" sensor
Machine Safety
Performance level with AWAX controller: PL = e in accordance with ISO 13849-1
Safety category: 4 in accordance with ISO 13849-1
Time before dangerous failure: MTTFd = 120 years
Cycle before dangerous failure: B10d=100,000 at 5A
Risk duration: 20 ms max.
Cable severing protection: yes (opening of safety lines)
Short-circuit protection and overload protection: yes (system shutdown). Requires return to a service workshop for a total control and troubleshooting.
Safety contacts/diagnostics: 3x NO 8A/250V redundant / 1x NF 8A/250V redundant parallel Indicators: 3 LEDs
Reset: configurable by dip-switch (SR=Automatic, N=manual)
Mounting: symmetrical DIN 35mm rail on DIN 50022
Mounting: IP 54 electrical box
Electrical connection: Maximum 14 AWG (2.08 mm²) / 250V minimum
Temperature: -20°C to +40°C.
Certification: INERIS 06ATEX0007X
RX-8564LC
Interface type:IC-Bus Interface (400 kHz)
Operating voltage range:1.8 V to 5.5 V
Timekeeper voltage range:1.0 V to 5.5 V / -20°C to + 70 °C
Low backup current:275 nA / 3.0 V(Typ.)
32.768 kHz frequency output function:C-MOS output With Control Pin
This document provides guidance on how to use the RDKGS12070 Reference Design board. It is recommended that the GS12070 Data Sheet (PDS061012) is read prior to reading this document in order to get familiarized with the features of the GS12070.
The RDKGS12070 can be poweredup and evaluated outofthebox as a standalone kit without GUI control. Connecting to a PC (using the supplied USB cable) enables evaluation of the advanced features which are only accessible through the host interface. However, the following features are among those which are available outofthebox without any programming required
MUX Mode with multiple conversion mode options
DEMUX Mode with multiple conversion mode options
Fourlane Bypass Mode for all supported rates including SD
75% colour bars pattern generator for all supported rates